Torq N Seal Medium Pressure Tube Plugs
Made-to-order Torq N Seal Medium Pressure heat exchanger tube plugs for service up to 1,000 psi. Metal-to-metal sealing with a wider ID expansion range. Use the material and sizing selector to prepare your enquiry; Justram confirms the final plug and lead time.
Torq N Seal Medium Pressure tube plugs create a permanent metal-to-metal mechanical seal for heat exchanger service up to 1,000 psi (6.9 MPa), subject to the selected plug, material and application. Their wider expansion range helps accommodate variation in tube inside diameter and can reduce the number of plug sizes needed for a turnaround.
Made to order. Contact Justram to confirm the size, alloy, quantity and lead time for your application.
Select a Medium Pressure plug · Download technical documents
Wider expansion for process heat exchangers
The Medium Pressure design suits applications such as process exchangers, condensers, fin-fan coolers and preheaters operating within its confirmed limits. Installation uses a hand-operated torque wrench and the appropriate driver to expand the plug within the supported tubesheet area.
- Service pressure: up to 1,000 psi; confirm the selected plug and application.
- Seal: mechanical metal-to-metal contact.
- Expansion: wider than the High Pressure design. The cut sheet advertises up to 0.090 inch; the May 2022 report describes approximately 0.060 inch for its tested design. Confirm the actual minimum and maximum ID for the ordered plug.
- Temperature: depends on the selected alloy and service. Request the applicable temperature limit with your quotation.
- Availability: made to order, with lead time confirmed at quotation.
Torq N Seal medium-pressure plug selector
Start with your tube size, choose the tube material, then review the details before adding them to your enquiry. On-site measured ID is the preferred sizing method.
Enable JavaScript to use the selector, or consult the reference table below and contact Justram.
1. Tube size
Preferred: Measure the actual bore at the intended plug expansion area using an inside tube micrometer or gauging block. This captures as-found dimensions and tubing tolerances, particularly for minimum-wall tubing.
Where and how to measure
- Remove loose scale and corrosive oxide deposits that could affect the reading.
- Measure within the supported tube/tubesheet interface, where the plug’s expansion area will sit.
- Measure past welds and indentations, not across a weld overhang.
An overhanging weld may require assessment and reaming to admit the correctly sized plug. Confirm preparation and installation procedures before altering the bore.
Your measurement is retained exactly as entered. No nominal-ID formula, rounding or rolling allowance is applied.
Tube size and gauge guide
Average-wall assumption: This OD/BWG guide assumes average-wall tubing. Minimum-wall tubing requires a different tube-ID calculation; do not use this chart to select its plug. Contact Justram with the tube specification and actual measured ID.
Contact Justram about minimum-wall tubing
Secondary reference only. Nominal ID is OD minus twice the stated wall thickness; no rolling allowance is added. Tube tolerances, wear and rolling can change the actual bore. Confirm the expansion-zone ID before ordering.
2. Tube material
Select the tube’s material. Justram will confirm the final plug alloy and part designation for your service.
Medium Pressure material suffixes
These suffixes come from the Medium Pressure cut sheet. Generic alloy families require an exact grade when ordering. All plugs are made to order.
| Suffix | Tube material |
|---|---|
| CS | Carbon Steel |
| BR | Brass |
| 316SS | 316 Stainless Steel |
| 304SS | 304 Stainless Steel |
| 321SS | 321 Stainless Steel |
| TI | Titanium |
| DP | Duplex |
| SDP | Super Duplex |
| IN | Inconel |
| C276 | Hastelloy C276 |
| F11 | Alloy steel — F11 (confirm grade) |
| MN | Monel |
| 70CN | 70/30 Copper Nickel |
| 90CN | 90/10 Copper Nickel |
The source pairs suffix F11 with “A182-T11”; the grade designation needs confirmation before ordering.
Include tubesheet material, process fluid, pressure, temperature and certification requirements in your enquiry.
3. Review and enquire
Minimum quantity: 10 plugs.
Enter your tube ID
A sizing reference is not approval for service. Justram must confirm the measured bore, plug alloy and application before ordering.
Your enquiry list
Cut-sheet chart coverage: 5/8, 3/4, 7/8 and 1 inch tube OD, 12–22 BWG; listed nominal IDs 0.407–0.944 inches. Enquire about other sizes.
Tube size & BWG sizing guide — average-wall tubing
Assumes average-wall tubing. For minimum-wall tubing, the tube-ID calculation differs: contact Justram. Dimensions are in inches. Base plug references below are transcribed from the Medium Pressure cut sheet and exclude the material suffix. They are nominal-size references, not a table of minimum and maximum sealing IDs. Nominal tube ID = OD − 2 × wall thickness.
| Tube OD | BWG | Wall | Tube ID | Base plug |
|---|---|---|---|---|
| 5/8″ | 12 | 0.109 | 0.407 | MP-400 |
| 5/8″ | 13 | 0.095 | 0.435 | MP-430 |
| 5/8″ | 14 | 0.083 | 0.459 | MP-450 |
| 5/8″ | 15 | 0.072 | 0.481 | MP-480 |
| 5/8″ | 16 | 0.065 | 0.495 | MP-490 |
| 5/8″ | 17 | 0.058 | 0.509 | MP-500 |
| 5/8″ | 18 | 0.049 | 0.527 | MP-520 |
| 5/8″ | 19 | 0.042 | 0.541 | MP-540 |
| 5/8″ | 20 | 0.035 | 0.555 | MP-550 |
| 5/8″ | 21 | 0.032 | 0.561 | MP-560 |
| 5/8″ | 22 | 0.028 | 0.569 | MP-560 |
| 3/4″ | 12 | 0.109 | 0.532 | MP-530 |
| 3/4″ | 13 | 0.095 | 0.560 | MP-560 |
| 3/4″ | 14 | 0.083 | 0.584 | MP-580 |
| 3/4″ | 15 | 0.072 | 0.606 | MP-600 |
| 3/4″ | 16 | 0.065 | 0.620 | MP-620 |
| 3/4″ | 17 | 0.058 | 0.634 | MP-630 |
| 3/4″ | 18 | 0.049 | 0.652 | MP-650 |
| 3/4″ | 19 | 0.042 | 0.666 | MP-660 |
| 3/4″ | 20 | 0.035 | 0.680 | MP-680 |
| 3/4″ | 21 | 0.032 | 0.686 | MP-680 |
| 3/4″ | 22 | 0.028 | 0.694 | MP-690 |
| 7/8″ | 12 | 0.109 | 0.657 | MP-650 |
| 7/8″ | 13 | 0.095 | 0.685 | MP-680 |
| 7/8″ | 14 | 0.083 | 0.709 | MP-700 |
| 7/8″ | 15 | 0.072 | 0.731 | MP-730 |
| 7/8″ | 16 | 0.065 | 0.745 | MP-740 |
| 7/8″ | 17 | 0.058 | 0.759 | MP-750 |
| 7/8″ | 18 | 0.049 | 0.777 | MP-770 |
| 7/8″ | 19 | 0.042 | 0.791 | MP-790 |
| 7/8″ | 20 | 0.035 | 0.805 | MP-800 |
| 7/8″ | 21 | 0.032 | 0.811 | MP-810 |
| 7/8″ | 22 | 0.028 | 0.819 | MP-810 |
| 1″ | 12 | 0.109 | 0.782 | MP-780 |
| 1″ | 13 | 0.095 | 0.810 | MP-810 |
| 1″ | 14 | 0.083 | 0.834 | MP-830 |
| 1″ | 15 | 0.072 | 0.856 | MP-850 |
| 1″ | 16 | 0.065 | 0.870 | MP-870 |
| 1″ | 17 | 0.058 | 0.884 | MP-880 |
| 1″ | 18 | 0.049 | 0.902 | MP-900 |
| 1″ | 19 | 0.042 | 0.916 | MP-910 |
| 1″ | 20 | 0.035 | 0.930 | MP-930 |
| 1″ | 21 | 0.032 | 0.936 | MP-930 |
| 1″ | 22 | 0.028 | 0.944 | MP-940 |
Confirm the plug’s working range
Chart references are a starting point for an enquiry. The actual measured bore, sealing-area condition, selected material and confirmed plug expansion range determine final selection. Do not apply a single expansion allowance to every part.
The brochure gives one specific example: MP-820-CS covers 0.820–0.880 inch ID, including its 1 inch OD × 14 BWG example (0.834 inch nominal ID). The cut-sheet chart lists MP-830 for that same nominal tube size. Justram will confirm the appropriate plug for the measured bore.
Installation and application review
Use a suitable 3/8-inch square-drive torque wrench with the correct Hex Capture Driver. Confirm the driver and installation torque for the supplied Medium Pressure plug using its label and applicable instructions. Keep the sealing area within the supported tubesheet depth. Have the actual bore and sealing-area condition assessed before selection or installation.
Hydrostatic test documentation
The report dated 1 May 2022 describes testing of carbon-steel and 316-stainless plugs in 0.620-inch-ID fixtures, using plugs with a stated 0.560–0.620-inch range. It reports hydrostatic testing at 2,500 psi and additional prolonged-service, thermal-cycle, pressure-cycle and vibration tests. These are test conditions; the stated product service rating remains up to 1,000 psi. Confirm applicability to your selected size, alloy and operating conditions.
Include the installation province, applicable code and any CRN or nuclear documentation requirements with your enquiry so coverage for the supplied plugs can be checked.
Technical documents
Use the documents below for technical reference. Justram supplies these Medium Pressure plugs made to order; any off-the-shelf availability wording in the cut sheet does not describe current Justram availability.
- Medium Pressure cut sheet and selection chart (PDF, 2 pages)
- Heat exchanger tube plug comparison brochure (PDF, 2 pages)
- Medium Pressure hydro test report — 1 May 2022 (PDF, 13 pages)
Compare Torq N Seal tube plugs
Compare the Torq N Seal High Pressure tube plugs or elastomer condenser plugs. Each design has its own service limits, sizing and installation requirements. Browse all heat exchanger tube plugs.